Frequency Inverter LS 0370S100-4EOFNS

€2,494.30*

Product number:
6031001400
Shipping fees:
Article + Packaging
Product information "Frequency Inverter LS 0370S100-4EOFNS"

Frequency inverter, VFD- 37kW, 380V- 400C- 420V- 480V, IP20, built- in LED keypad, EMC filter (C3)

  • 0.1-400Hz frequency output
  • 1-15kHz carrier frequency
  • Constant torque / Variable torque dual rating
  • Selectable V/f and sensorless vector control
  • Powerful torque at overall Speed range
  • Fault history: Last 5 faults
  • High performances & functions: KEB (Kinetic Energy Buffering) protection,
    Ride Through (LV Trip Delay) protection, Under Load Trip protection,
    Power brake & Flux Brake function, Static motor parameter Auto-tuning
  • Enhanced process PID control with Sleep & Wake-up functions
  • Low leakage PWM algorism
  • Available IP66 enclosure (0.4-22kW) as built-in option
  • Built-in Dynamic braking transistor (0.75-22kW)
  • Available EMC Filter & DC Reactor as built-in option
  • Wide graphic LCD keypad (30-75kW)
  • Remote control using external wide graphic LCD keypad
  • Cooling fan On/Off control & Easy change
  • Extension I/O boards (Optional): 11 max. inputs & 6 max outputs
  • 0-10Vdc / -10-+10Vdc analog input
  • Selectable PNP/NPN input signal
  • Built-in RS485 (LS Bus / Modbus RTU) communication
  • Communication boards (Optional): Profibus-DP, Ethernet, EtherCAT, Profinet, CANopen
  • Monitoring & commissioning PC based software tool (Drive View)

              

             

 

Properties "Frequency Inverter LS 0370S100-4EOFNS"
Manufacturer: LS
Performance: 37 kW
Protection class: IP20
Series: S100 - the Modern
Tension: 3 x 400 V

Accesories

LS EtherCAT
LS EtherCAT interface card only for S100. All product photos are non-binding examples! Technical changes reserved.

€164.62*
Right/left switch, emergency stop for FU
Right-left rotation switch with emergency stop in a plastic housing Switch does not latch. External frequency converter control. Optionally with 1m, 3m or 5m cable (wired). Please select the version. All product photos are non-binding examples! Technical changes reserved.

From €171.65*
Right-left-turn switch for VFD
Right-left rotation switch with potentiometer and emergency stop in a plastic housing. Switch not latching. External frequency converter control. Potentiometer connection solder contacts 1 NO contact each for left and right rotation Housing dimensions in mm (WxHxD): 160x80x55 Color: similar to RAL7035 Potentiometer: 2.2k / 2W, rotation angle 270 °, rotary knob : 32mm cable gland: M16, clamping range 5-10mm degree of protection: IP65, for connection in the control circuit Optionally without or with 1m, 3m or 5m cable (wired). Please choose version. All product photos are non-binding examples!

From €382.79*
Motor connection cable shielded 4 x 1.5 mm²
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid. Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 11.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!

From €3.81*
LS S100 remote LED keypad
External control panel for installation in the control cabinet for M100 series. Optionally with 2m, 3m, or 5m connection cable. All product photos are non-binding examples! Technical changes reserved.

From €45.90*
LS S100, IS7 mounting frame with cable
Installation frame for LCD control panel for S100 and IS7 series With 3m cable, also in protection class IP66. Please select. All product photos are non-binding examples! Technical changes reserved.

From €23.97*
Potentiometer- 0-10KΩ
Potentiometer, 0-10KΩ, suitable for control cabinet mounting. This stepless rotary potentiometer can be used for the complete range of LS frequency inverters. The potentiometer can be connected via screw terminals, no soldering is required. Suitable for installation in the control cabinet.

€25.36*
Foot switch with metal housing F1-AU0-10V
Rated operational Voltage Ue 12-26 V DC Utilization category DC-13 Ue / Ie 12-26 DC / 0.2 A according to IEC / EN 60947-5-2 Voltage output (control range) 0- 10 V DC short-circuit protection device switching element permanent short-circuit u. overload-proof, clocking Protection class IIIM UB GND RL U-OUT U-OUT housing AL die-cast; Lid die-cast aluminum actuating elements foot pedal (PA) ambient temperature -30 ° C to +80 ° C contact type PNP closer, teachbar from 0.1 - 5.9 mm switching force pedal approx. 10 N (center of pedal) Mechanical life 10 x 106 switching cycles and switching frequency max. 50 / min; Fastening 2 M8 screws connection type screw connections (M3.5) number of connections 4, conductor cross sections solid 0.5 - 1.5 mm2 stranded wire with ferrule 0.5 - 1.5 mm2, cable entry 1 x M20 x 1.5 weight 1.5 kg, Protection class IP65 according to IEC / EN 60529 drawing ID: Z030  

€237.38*
Control cable shielded 7 x 1.0 mm²
Suitable for frequency inverters CPR performance class: Eca, conductor material: Cu, bare conductor class: class 5 = finely stranded, core insulation: PVC TI1 stranding element: core, sheath material: PVC YM2 sheath color: gray RAL 7001, flame retardant : VDE 0482-332-1-2 / IEC 60332-1-2 Maximum permissible conductor temperature: 70 ° C Perm. External cable temperature fixed: -40 - +70 ° C Perm. Outside cable temperature, in motion -5 - +70 ° C bending radius, fixed installation: 6 x Ø, bending radius, moving: 20 x Ø nominal Voltage Uo: 300 V, nominal Voltage U: 500 V core identification: green -yellow + digits cable diameter approx. 10.1 mm Please select the cable length and the equipment. All product photos are non-binding examples! Technical changes reserved.

From €10.19*
Right/left switch, potentiometer for FU
Right-left rotation switch with potentiometer in a plastic housing Switch latching. External frequency converter control. Optionally without or with 1m, 3m or 5m cable (wired). Please select the version. All product photos are non-binding examples! Technical changes reserved.

From €89.79*
LS S100 / IS7 USB-cabel
USB cable for S100 / IS7 / H100. (RJ45 > USB)

€33.38*
LS S100, IS7 LCD control panel without cable
External LCD control panel for installation in the control cabinet for S100 and IS7 series Protection class: IP21 All product photos are non-binding examples! Technical changes reserved.

€72.04*
LS Profibus
LS Profibus interface card only for S100, IS7 or G100. Please select series. All product photos are non-binding examples! Technical changes reserved.

From €174.60*