Frequency Inverter LS 0055H100-4COFN

€700.52*

Delivery time on demand

Product number:
6731002900
Shipping fees:
Article + Packaging
Product information "Frequency Inverter LS 0055H100-4COFN"

Frequency inverter for pump / fan operation, 5.5 kW, 400V, IP20, EMC filter (C3)

Specific functions for pumps and fans
- MMC function (control of several motors)
- Time switch function (time event: real-time clock)
- flow compensation
- gentle filling
- Initial acceleration & final acceleration
- valve down ramp
- Pump cleaning
- load balancing
- Fire mode
- Energy saving display (amortization counter)
- Boost, wake-up function
- U / f control
- Integrated BACnet communication
- LonWorks (optional)
- Control panel especially for pumps / fans
- Integrated EMC filter / DC reactor
- Side by side installation
- Intermediate plate option
- Small size
- Condenser / fan life monitoring function
- Smart Copy function (flash drop, download of parameters and
of the main operating system possible without Voltage)

 

             

>

 

Properties "Frequency Inverter LS 0055H100-4COFN"
Performance: 5,5 kW
Protection class: IP20
Series: H100 - for pumps and fans
Tension: 3 x 400 V

Accesories

LS Smart Copier
Smart Copier for S100, IS7, M100, H100, G100 When using the Smart Copier, the inverter does not require a power supply. The Run LED flashes during normal operation. The Error LED flashes when faults(e.g. communication errors) occur. Parameters can be easily copied/loadedfrom the inverter to the Smart Copier and vice versa using the control unit. Firmware and parameters stored in the Smart Copier can be downloaded to both the inverter I/O and thecontrol unit. Firmware can be downloadedfrom a PC using a USB cable. R45 cable (included with the purchase of the Smart Copier). All product photos are non-binding examples! Technical changes reserved.

€1,234.68*
Foot switch with metal housing F1-AU0-10V
Rated operational Voltage Ue 12-26 V DC Utilization category DC-13 Ue / Ie 12-26 DC / 0.2 A according to IEC / EN 60947-5-2 Voltage output (control range) 0- 10 V DC short-circuit protection device switching element permanent short-circuit u. overload-proof, clocking Protection class IIIM UB GND RL U-OUT U-OUT housing AL die-cast; Lid die-cast aluminum actuating elements foot pedal (PA) ambient temperature -30 ° C to +80 ° C contact type PNP closer, teachbar from 0.1 - 5.9 mm switching force pedal approx. 10 N (center of pedal) Mechanical life 10 x 106 switching cycles and switching frequency max. 50 / min; Fastening 2 M8 screws connection type screw connections (M3.5) number of connections 4, conductor cross sections solid 0.5 - 1.5 mm2 stranded wire with ferrule 0.5 - 1.5 mm2, cable entry 1 x M20 x 1.5 weight 1.5 kg, Protection class IP65 according to IEC / EN 60529 drawing ID: Z030  

€237.38*
Motor connection cable shielded 4 x 1.5 mm²
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid. Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 11.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!

From €3.81*
LS S100, IS7 LCD control panel without cable
External LCD control panel for installation in the control cabinet for S100 and IS7 series Protection class: IP21 All product photos are non-binding examples! Technical changes reserved.

€72.04*
Potentiometer- 0-10KΩ
Potentiometer, 0-10KΩ, suitable for control cabinet mounting. This stepless rotary potentiometer can be used for the complete range of LS frequency inverters. The potentiometer can be connected via screw terminals, no soldering is required. Suitable for installation in the control cabinet.

€25.36*
Control cable shielded 7 x 1.0 mm²
Suitable for frequency inverters CPR performance class: Eca, conductor material: Cu, bare conductor class: class 5 = finely stranded, core insulation: PVC TI1 stranding element: core, sheath material: PVC YM2 sheath color: gray RAL 7001, flame retardant : VDE 0482-332-1-2 / IEC 60332-1-2 Maximum permissible conductor temperature: 70 ° C Perm. External cable temperature fixed: -40 - +70 ° C Perm. Outside cable temperature, in motion -5 - +70 ° C bending radius, fixed installation: 6 x Ø, bending radius, moving: 20 x Ø nominal Voltage Uo: 300 V, nominal Voltage U: 500 V core identification: green -yellow + digits cable diameter approx. 10.1 mm Please select the cable length and the equipment. All product photos are non-binding examples! Technical changes reserved.

From €10.19*
LS S100 / IS7 USB-cabel
USB cable for S100 / IS7 / H100. (RJ45 > USB)

€33.38*